Item Novalon® PVC Free Wallcovering
Description 54” Olefin Wallcovering
Content Highly Reinforced Olefin Composite
Specs Custom colors, widths, and micro venting are available
Embossing Select custom embossings available
Physical Properties
Trim Width 54” / 132-137 cm
Total Weight True Type II 20 oz*
Total Weight Metric 452 g/m2
Fabric Type Osnaburg Woven Backing
Backing Fabric Weight 2.0 oz/yd2
Average Total Thickness 20 mils
Standard Bolt Size (Custom avail) 30 Yards
*Type II Properties
Federal Specification -This wallcovering meets or exceeds all requirements of GSA Federal Specification CCC-W-408D for True Type II material as defined by WA-101
Including ASTM G2l - Mildew Resistance
Industry Standard - This wallcovering meets or exceeds all requirements of the Wallcovering Association Quality Standard wallcovering - WA-101-2017
Fire Hazard Classification Results
Tested in accordance with ASTM E-84 Tunnel Test Passed Class A
NFPA Life Safety Code 101 Passed Canadian CAN/ULC - S102.2 Passed
EU Reaction to Flame (EN 15102) Passed B S1 D0
Environmental — All versions
Manufactured without the use of PVC, Formaldehyde, Phthalates, Plasticizers, Antimicrobials, Phenol, or Brominated Flame retardants
15% Post- Consumer Recycled Content
Meets or exceeds EN12 149 A,B,C - the EU Toxicity requirement for heavy metals (including Cadmium, Mercury, Lead Phenol, and Antimony), and formaldehyde under EN 15102.
Printed with Water-Based Inks
Indoor Air Quality - Manufactured with Low VOC emissions
- Meets California CDPH Standard for Schools and Offices
- Tested per CA 01350
LEED – LEED compliant and can contribute to Paragraphs EQ 4.1 for low emitting materials, and MR 5.1 for regional materials, & v4 for Postconsumer recycled content.
NSF – 342 Certification - Pending
Strippability — All versions
All constructions are fully strippable when hung with commonly available commercial wallcovering adhesive Instructions
Hanging and Cleaning Instructions
Wall construction - This product is intended for use in buildings designed and maintained to avoid moisture accumulation on or within walls, particularly in warm humid climates. The features that make wallcovering durable also render it low in permeability. Wallcovering should not be installed on walls that contain excess moisture, or are subject to moisture infiltration. Processes to increase permeability, such as micro-venting, combined with the use of primers and adhesives with the highest permeability rating are recommended.
Roysons Exclusive and Limited 5-Year Warranty against Manufacturing Defects Yes
40 Vanderhoof Ave. | Rockaway, New Jersey 07866 | roysons.com | p 973.625.5570 | f 973.625.5917